product

Products

...

Cardiac Monitor

Cardiac Monitor

Model: OMNI III

Make:  Infinium Medical, Inc,

Country of Oriin : USA

 

Features

 Designed for a fast paced work environment with extremely simple and adaptable user interface. Patient information along with vital sign settings should have capability for quickly modified to meet the needs of a patient’s changing condition.  High resolution minimum 12 inch touch screen  Quick screen adjustments, set default settings, alarm limits, and manage up to 72 hours of detailed patient data.  Standard measurements of non-invasive blood pressure, ECG with arrhythmia detection, motion tolerant SpO2, Temperature, End-tidal CO2, Invasive blood pressure, Respiration rate and 3 modules of Cardiac Output against 10 monitors (can added on-site by simply attaching plug in modules).  End-tidal CO2, Invasive blood pressure, Cardiac Output & Anesthetic Agent measurement modules can be added on-site by simply attaching plug in modules.  Upgradability to acuity level while the patient’s condition changes. Anesthetic Agent measurement can added on-site by simply attaching plug in modules.  Networking facility to multiple monitors and/or manage patient data on an electronic medical records platform or a HL7 based hospital information system.  Should have Ethernet and RS-232 connections with an open source communication protocol. OxyCRG, drug dose calculation, cascading ECG,  On screen NIPB trends (up to 250 readings),  user set defaults, Arrhythmia detection, ST segment Specification ECG:  Input: 5-lead ECG cable  Lead Choice : I, II, III, aVR, aVF, aVL, V, V1-V6, TEST  Gain Choice : x0.5, x1, x2, x4  Frequency Characteristic : 0.05 ~ 35 HZ (+3dB)  ECG Waveforms : 7 channels  Penetration Voltage : 4000VAC 50/60Hz  Sweep Speed : 12.5, 25, 50 and 100 mm/sec (left to right or right to left)  HR Display Range : 30 ~ 300bpm  Accuracy : ±1bpm or ±1%, whichever is greater  Alarm Limit Range Setting: upper limit 100 ~ 200bpm, lower limit 30 ~ 100bpm RESP  Measure Method : RA-LL impedance  Range : 0 ~ 120 rpm  Accuracy : ±3 rpm  Alarm Limit Setting : upper limit 6 ~ 120 rpm, lower limit 3 ~ 120 rpm  Sweep Speed :12.5, 25, 50 and 100 mm/sec (left to right or right to left) NIBP  Measuring Technology: automatic oscillating measurement  Cuff Inflating : <30s (0 ~ 300 mmHg, standard adult cuff)  Measuring Period : AVE<40s  Mode : Manual, Auto Measuring Interval in  AUTO Mode : 2 min ~ 4 hrs  Pulse Rate Range : 30 ~ 250 (bpm)  Adult/Pediatric Mode: SYS : 40 ~ 250 (mmHg) DIA :15 ~ 200 (mmHg)  Neonatal Mode : SYS: 40 ~ 135 (mmHg) DIA : 15 ~ 100 (mmHg) Accuracy:  Maximum Mean error: ±5mmHg  Maximum Standard deviation: 8mmHg NIBP (continued)  Resolution: 1mmHg  Overpressure Protection : Adult Mode: 300 (mmHg) Neonatal Mode: 160 (mmHg)  Alarm Limit Setting : SYS: 50 ~ 240 mmHg DIA: 15 ~ 180 mmHg TEMP  Range : 25 ~ 50 (°C)  Accuracy: ± 0.2°C (25.0 ~ 34.9°C) ± 0.1°C (35.0 ~ 39.9°C) ± 0.2°C (40.0 ~ 44.9°C) ± 0.3°C (45.0 ~ 50.0°C)  Display Resolution : 0.1°C  Alarm Limit Setting : upper limit 0 ~ 50°C, lower limit 0 ~ 50°C  Channel: 12 Channel Spo2  ASpO2 : Anti-motion SpO2  SpO2% Range : 0-100%  SpO2 Accuracy : ±2% (70 ~ 100%, non-motion) ±3% (70 ~ 100%, motion)  Pulse Rate Range : 30-250 bpm  Pulse Rate Accuracy : ±2 bpm (non-motion ±3 bpm (motion)  Alarm Limit Setting: upper limit 70 ~ 100%, lower limit 70 ~ 100%  SpO2 Probe : Red light LED wavelength 660nm±5nm Infrared light LED wavelength 940nm±10nm IBP  Measurement Range : -50 ~ 300mmHg  Channel : 2 channels  Pressure Transducer : sensitivity, 5µV/V/mmHg  Impedance Range : 300 ~ 3000Ω  Transducer Sites : ART, PA,CVP, RAP, LAP, ICP  Unit : mmHg/kPa selectable  Resolution : 1mmHg  Accurancy : ±1mmHg or ±2%, whichever is greater  Alarm Range : -10 ~ 300mmHg ETCO2  CO2 Measurement Range : 0 ~ 99mmHg  Accuracy : ±2mmHg (0 ~ 38mmHg) 39-99mmHg ±5% of reading +0.08% for every 1mmHg (above 38mmHg)  Sampling Rate : 50 ml/min  Initialization Time : 30 seconds (typical), reaches ±5% steady-state accuracy within 3 minutes.  Respiration Rate: 0 ~ 150 breaths/min  Mode: adult, neonate C.O. (Cardiac output) – total 03 modules for 10 monitors should be supplied.  Measurement Method : Thermodilution Method  Measurement Range : C.O. 0.1 to 20 L/min TB 23 to 43 TI 0 to 27  Resolution : C.O. 0.1 L/min TB, TI 0.1  Accuracy : C.O. ±5% or ±0.1 L/min, which- ever is greater, as measured using electronically generated flow curves. TB, TI ±0.1 (without sensor)  Alarm Range TB 23 to 43  Repeatability : C.O. ±2% or ±0.1 L/min, which- ever is greater, as measured using electronically generated flow curves Power  Source : External AC power or internal battery  AC Power : 100 ~ 240VAC, 50Hz, 150VA  Battery : Built-in & rechargeable lithium ion  Operating Time : 3+ hours