product

Products

...
·   Diagnose Faster - Within a minute obtain results for airway resistance, dynamic/static lung volumes and flow/volume curve.

·   Maintenance Free - Clean and high-precision via

·   Ultrasound Technology.

·   Longlife Gas Analyzers - No replacements or periodic changes needed.

·   Broad Spectrum Of Option - Multiple programs available, making the PowerCube Body+ your comprehensive analysis device.

·   Cost & Space - optimized.

·   Ats/Ers Guideunes - Fully conforms to Gold Standards.

·   LFX: Our User-Friendly Intuitive Software - Latest programming technologies safeguard natural day to day workflow.

 

Technical Data:

Flow-Measurement

-    Principle              : Ultrasound Transit Time

-    Range                 : 0 - 20 l/s

-    Accuracy           : ± 2% or 50 ml/s (whichever is greater)

-    Resistance         : <0.05 kPa/(l/s) at 14 l/s

 

Volume-Measurement

Principle : Digital Integration

Range                    : Not limited

Accuracy               : ± 2% or 50 ml/s (whichever is greater)

Mouth Pressure

Principle                 : Piezo resistive

Range                    : ± 30 kPa

Accuracy               : ± 1%

 

Cabin Pressure

Principle : Piezo resisitive

Range                    : ± 1 kPa

Accuracy               : ± 1%

 

CO Analyzer

Principle : Non-dispersive Infrared Analyzer

Range                    : 0 - 0.5%

Accuracy               : ± 1%

 

He Analyzer

Principle : Ultrasound

Range                    : 0 - 20 % He

Accuracy               : ± 1% ‘] ,1

 

Weight

Weight of cabin   : 150 kg AT%

Dimensions

W/o door Handle : 86 cm x 185 cm x 71 cm

 

Electrical Requirements

Power Consumption : Max. 120 VA

Voltage                  : 24 V

Frequency             : 50/60 Hz

 

 

 

FEATURES

 

COMPLETE PACKAGE.

Includes ergonomic trolley, PC, monitor, printer and isolating transformer.

 

WHEEL-CHAIR & XL-CABIN AVAILABLE.

Increased comfort for exceptional patients.

 

MAXIMUM COOPERATION.

Panorama view and LED-Lights for maximum patient comfort.

 

ADMINISTRATIVE PROGRAMS

§  SQL Database

§  Report Generator

§  Multiuser license

§  User Predicted Values

§  GDT data transfer

§  HL7 Interface

§  Worklist

§  DICOM

 

MEASUREMENT PROGRAMS & FEATURES

§ Bodyplethysmography (TGV)

§ Airway resistance (Eff, Tot, 0.5, mid, peak)

§ Slow Spirometry

§ Forced Spirometry/Flow-Volume

§ Single Breath Diffusion

§ FRC - Nitrogen Washout

§ Offline Input of Bloodgases

§ Provocation Rhinomanometry

§ ROCC

§ MIP/MEP (Muscle Strength)

§ MVV

§ ROS/FOT

§ Compliance

§ Capnovolumetry

-->

Complete Respiratory Diagnostics System

Complete Respiratory Diagnostics System

 

Model: POWERCUBE BODY+

Make: GANSHORN MEDIZIN  ELECTRONIC  GMBH”

Country of Origin: Germany

 

Full pulmonary function testing lab including recording of all pulmonary volumes and diffusing capacity

 

·   Diagnose Faster - Within a minute obtain results for airway resistance, dynamic/static lung volumes and flow/volume curve.

·   Maintenance Free - Clean and high-precision via

·   Ultrasound Technology.

·   Longlife Gas Analyzers - No replacements or periodic changes needed.

·   Broad Spectrum Of Option - Multiple programs available, making the PowerCube Body+ your comprehensive analysis device.

·   Cost & Space - optimized.

·   Ats/Ers Guideunes - Fully conforms to Gold Standards.

·   LFX: Our User-Friendly Intuitive Software - Latest programming technologies safeguard natural day to day workflow.

 

Technical Data:

Flow-Measurement

-    Principle              : Ultrasound Transit Time

-    Range                 : 0 - 20 l/s

-    Accuracy           : ± 2% or 50 ml/s (whichever is greater)

-    Resistance         : <0.05 kPa/(l/s) at 14 l/s

 

Volume-Measurement

Principle : Digital Integration

Range                    : Not limited

Accuracy               : ± 2% or 50 ml/s (whichever is greater)

Mouth Pressure

Principle                 : Piezo resistive

Range                    : ± 30 kPa

Accuracy               : ± 1%

 

Cabin Pressure

Principle : Piezo resisitive

Range                    : ± 1 kPa

Accuracy               : ± 1%

 

CO Analyzer

Principle : Non-dispersive Infrared Analyzer

Range                    : 0 - 0.5%

Accuracy               : ± 1%

 

He Analyzer

Principle : Ultrasound

Range                    : 0 - 20 % He

Accuracy               : ± 1% ‘] ,1

 

Weight

Weight of cabin   : 150 kg AT%

Dimensions

W/o door Handle : 86 cm x 185 cm x 71 cm

 

Electrical Requirements

Power Consumption : Max. 120 VA

Voltage                  : 24 V

Frequency             : 50/60 Hz

 

 

 

FEATURES

 

COMPLETE PACKAGE.

Includes ergonomic trolley, PC, monitor, printer and isolating transformer.

 

WHEEL-CHAIR & XL-CABIN AVAILABLE.

Increased comfort for exceptional patients.

 

MAXIMUM COOPERATION.

Panorama view and LED-Lights for maximum patient comfort.

 

ADMINISTRATIVE PROGRAMS

§  SQL Database

§  Report Generator

§  Multiuser license

§  User Predicted Values

§  GDT data transfer

§  HL7 Interface

§  Worklist

§  DICOM

 

MEASUREMENT PROGRAMS & FEATURES

§ Bodyplethysmography (TGV)

§ Airway resistance (Eff, Tot, 0.5, mid, peak)

§ Slow Spirometry

§ Forced Spirometry/Flow-Volume

§ Single Breath Diffusion

§ FRC - Nitrogen Washout

§ Offline Input of Bloodgases

§ Provocation Rhinomanometry

§ ROCC

§ MIP/MEP (Muscle Strength)

§ MVV

§ ROS/FOT

§ Compliance

§ Capnovolumetry