Vital Sign Monitor

Vital Sign Monitor

Model: OMNI II

Make: Infinium Medical, Inc

Country of Origin: USA

 

 

Features • Designed for a fast paced work environment with extremely simple and adaptable user interface. Patient information along with vital sign settings should have capability for quickly modified to meet the needs of a patient’s changing condition. • High resolution min 10 inch touch screen • Quick screen adjustments, set default settings, alarm limits, and manage up to 72 hours of detailed patient data. • Standard measurements of non-invasive blood pressure, ECG with arrhythmia detection, motion tolerant SpO2, Temperature, and Respiration rate. • Upgradability to acuity level while the patient’s condition changes. End-tidal CO2, Anesthetic Agent measurement, Cardiac Output and Invasive blood pressure can added on-site by simply attaching plug in modules. • Networking facility to multiple monitors and/or manage patient data on an electronic medical records platform or a HL7 based hospital information system. • Should have Ethernet and RS-232 connections with an open source communication protocol. OxyCRG, drug dose calculation, cascading ECG, • On screen NIPB trends (up to 250 readings), • user set defaults, Arrhythmia detection, ST segment Specification ECG  Input: 5-lead ECG cable  Lead Choice : I, II, III, aVR, aVF, aVL, V, V1-V6, TEST  Gain Choice : x0.5, x1, x2, x4  Frequency Characteristic : 0.05 ~ 35 HZ (+3dB)  ECG Waveforms : 7 channels  Penetration Voltage : 4000VAC 50/60Hz  Sweep Speed : 12.5, 25, 50 and 100 mm/sec (left to right or right to left)  HR Display Range : 30 ~ 300bpm  Accuracy : ±1bpm or ±1%, whichever is greater  Alarm Limit Range Setting: upper limit 100 ~ 200bpm, lower limit 30 ~ 100bpm RESP  Measure Method : RA-LL impedance  Range : 0 ~ 120 rpm  Accuracy : ±3 rpm  Alarm Limit Setting : upper limit 6 ~ 120 rpm, lower limit 3 ~ 120 rpm  Sweep Speed :12.5, 25, 50 and 100 mm/sec (left to right or right to left) NIBP  Measuring Technology: automatic oscillating measurement  Cuff Inflating : <30s (0 ~ 300 mmHg, standard adult cuff)  Measuring Period : AVE<40s  Mode : Manual, Auto Measuring Interval in  AUTO Mode : 2 min ~ 4 hrs  Pulse Rate Range : 30 ~ 250 (bpm)  Adult/Pediatric Mode: SYS : 40 ~ 250 (mmHg) DIA :15 ~ 200 (mmHg)  Neonatal Mode : SYS: 40 ~ 135 (mmHg) DIA : 15 ~ 100 (mmHg) Accuracy:  Maximum Mean error: ±5mmHg  Maximum Standard deviation: 8mmHg  Resolution: 1mmHg  Overpressure Protection : Adult Mode: 300 (mmHg) Neonatal Mode: 160 (mmHg)  Alarm Limit Setting : SYS: 50 ~ 240 mmHg DIA: 15 ~ 180 mmHg TEMP  Range : 25 ~ 50 (°C)  Accuracy: ± 0.2°C (25.0 ~ 34.9°C) ± 0.1°C (35.0 ~ 39.9°C) ± 0.2°C (40.0 ~ 44.9°C) ± 0.3°C (45.0 ~ 50.0°C)  Display Resolution : 0.1°C  Alarm Limit Setting : upper limit 0 ~ 50°C, lower limit 0 ~ 50°C  Channel: 12 Channel Spo2  ASpO2 : Anti-motion SpO2  SpO2% Range : 0-100%  SpO2 Accuracy : ±2% (70 ~ 100%, non-motion) ±3% (70 ~ 100%, motion)  Pulse Rate Range : 30-250 bpm  Pulse Rate Accuracy : ±2 bpm (non-motion ±3 bpm (motion)  Alarm Limit Setting: upper limit 70 ~ 100%, lower limit 70 ~ 100%  SpO2 Probe : Red light LED wavelength 660nm±5nm Infrared light LED wavelength 940nm±10nm Networking  Industry standard 802.11b/g wireless network Power  Source : External AC power or internal battery  AC Power : 100 ~ 240VAC, 50Hz, 150VA  Battery : Built-in & rechargeable lithium ion  Operating Time : 3+ hours