Vital Sign Monitor Model: OMNI II Make: Infinium Medical, Inc Country of Origin: USA
Features • Designed for a fast paced work environment with extremely simple and adaptable user interface. Patient information along with vital sign settings should have capability for quickly modified to meet the needs of a patient’s changing condition. • High resolution min 10 inch touch screen • Quick screen adjustments, set default settings, alarm limits, and manage up to 72 hours of detailed patient data. • Standard measurements of non-invasive blood pressure, ECG with arrhythmia detection, motion tolerant SpO2, Temperature, and Respiration rate. • Upgradability to acuity level while the patient’s condition changes. End-tidal CO2, Anesthetic Agent measurement, Cardiac Output and Invasive blood pressure can added on-site by simply attaching plug in modules. • Networking facility to multiple monitors and/or manage patient data on an electronic medical records platform or a HL7 based hospital information system. • Should have Ethernet and RS-232 connections with an open source communication protocol. OxyCRG, drug dose calculation, cascading ECG, • On screen NIPB trends (up to 250 readings), • user set defaults, Arrhythmia detection, ST segment Specification ECG Input: 5-lead ECG cable Lead Choice : I, II, III, aVR, aVF, aVL, V, V1-V6, TEST Gain Choice : x0.5, x1, x2, x4 Frequency Characteristic : 0.05 ~ 35 HZ (+3dB) ECG Waveforms : 7 channels Penetration Voltage : 4000VAC 50/60Hz Sweep Speed : 12.5, 25, 50 and 100 mm/sec (left to right or right to left) HR Display Range : 30 ~ 300bpm Accuracy : ±1bpm or ±1%, whichever is greater Alarm Limit Range Setting: upper limit 100 ~ 200bpm, lower limit 30 ~ 100bpm RESP Measure Method : RA-LL impedance Range : 0 ~ 120 rpm Accuracy : ±3 rpm Alarm Limit Setting : upper limit 6 ~ 120 rpm, lower limit 3 ~ 120 rpm Sweep Speed :12.5, 25, 50 and 100 mm/sec (left to right or right to left) NIBP Measuring Technology: automatic oscillating measurement Cuff Inflating : <30s (0 ~ 300 mmHg, standard adult cuff) Measuring Period : AVE<40s Mode : Manual, Auto Measuring Interval in AUTO Mode : 2 min ~ 4 hrs Pulse Rate Range : 30 ~ 250 (bpm) Adult/Pediatric Mode: SYS : 40 ~ 250 (mmHg) DIA :15 ~ 200 (mmHg) Neonatal Mode : SYS: 40 ~ 135 (mmHg) DIA : 15 ~ 100 (mmHg) Accuracy: Maximum Mean error: ±5mmHg Maximum Standard deviation: 8mmHg Resolution: 1mmHg Overpressure Protection : Adult Mode: 300 (mmHg) Neonatal Mode: 160 (mmHg) Alarm Limit Setting : SYS: 50 ~ 240 mmHg DIA: 15 ~ 180 mmHg TEMP Range : 25 ~ 50 (°C) Accuracy: ± 0.2°C (25.0 ~ 34.9°C) ± 0.1°C (35.0 ~ 39.9°C) ± 0.2°C (40.0 ~ 44.9°C) ± 0.3°C (45.0 ~ 50.0°C) Display Resolution : 0.1°C Alarm Limit Setting : upper limit 0 ~ 50°C, lower limit 0 ~ 50°C Channel: 12 Channel Spo2 ASpO2 : Anti-motion SpO2 SpO2% Range : 0-100% SpO2 Accuracy : ±2% (70 ~ 100%, non-motion) ±3% (70 ~ 100%, motion) Pulse Rate Range : 30-250 bpm Pulse Rate Accuracy : ±2 bpm (non-motion ±3 bpm (motion) Alarm Limit Setting: upper limit 70 ~ 100%, lower limit 70 ~ 100% SpO2 Probe : Red light LED wavelength 660nm±5nm Infrared light LED wavelength 940nm±10nm Networking Industry standard 802.11b/g wireless network Power Source : External AC power or internal battery AC Power : 100 ~ 240VAC, 50Hz, 150VA Battery : Built-in & rechargeable lithium ion Operating Time : 3+ hours |