*   MAINTENANCE FREE - ultrafast and long-life CO2 sensor.

*   DO IT YOURSELF - O2 sensor can be changed within a minute and without a technician.

*   GOLD STANDARD - In full compliance with the ATS recommendations.

*   FLEXIBILITY - Analysis of the results in a prefered way - 9 panel Wassermann diagram or individual setup of graphs.

*   USER-FRIENDLY - Automatic determination of anaerobic threshold by set method or manually.

 

TECHNICAL DATA

 

FLOW-MEASUREMENT

·   Principle              : Pneumotach       (variable                orifice)

·   Range                  : 0-20 l/s

·   Accuracy            : ±2%

·   Resolution          : 0,01 l/s

 

VOLUME-MEASUREMENT

·   Principle              : Digital Integration

·   Ventilation         : 300 l/min

·   Accuracy            : ± 2%

 

O2 MEASUREMENT

Principle :  Chemical Cell

Range : 10 to 45% O2

Resolution:  0.01% O2

Rise time : 80 ms

Accuracy : ± 0.1% O2

 

O2 MEASUREMENT

Principle :  Ultrasound

Range : 10 to 15% CO2

Resolution:  0.01% CO2

Rise time : <80 ms

Accuracy : ± 0.1% CO2

 

ELECTRICAL REQUIREMENTS

·   Power Consumption: Max. 30 VA

·   Voltage               : 24V

·   Frequency          : 50 to 60 Hz

 

POWERCUBE ERGO

Technical specifications

 

FEATURES

*    12 CHANEL ECG

- Use a full 12 chanel stress ECG or a pulse belt for sports application.

*    NON-INVASIVE MEASURING

- The only non-invasive method of measuring cardiac output.

*    PATIENT MANAGEMENT

- Easy patient management handling due to a shared database with other GANSHORN products or due to a full integration into SCHILLER SEMA.

 

 

ADMINISTRATIVE PROGRAMS

SQL Database                    

·    Report Generator                           

·    Multiuser license                            

·    User Predicted Values                   

·    GDT data transfer                         

·    HL7 Interface                

·    DICOM                            

·    Worklist                           

 

MEASUREMENT PROGRAMS & FEATURES        

·      Ergospirometry                               

·      Forced Spirometry/Flow-Volume               

·      Slow Spirometry                             

·      Offline Input of bloodgases (e.g. lactate)                  

·      MVV (Maximal Voluntary Ventilation)                    

·      Cardiac Output                              

·      Calorimetry                     

·      SpO2                

·      12-channel stress ECG                  

·      Polar pulse belt                               

·      Blood pressure measurement                      

·      Ergometer                        

·      Treadmil                          

·      Evaluation Software LFSport     

 

Quality Standards

·   Quality Management :  ISO 13485

·   FDA : 510(k) market clearance!*)

·   MDD 93/42/ECC :  CE Marked

·   Electrical safety :  EN 60601-1 (Third Edition)          

-->

Cardio Pulmonary diagnostic System

Cardio Pulmonary diagnostic System

 

Make: GANSHORN MEDIZIN  ELECTRONIC  GMBH”

Country of Origin: Germany

 

Complete assessment for the differential diagnosis and sportsmen condition evaluation

YOUR ADVANTAGES

*   MAINTENANCE FREE - ultrafast and long-life CO2 sensor.

*   DO IT YOURSELF - O2 sensor can be changed within a minute and without a technician.

*   GOLD STANDARD - In full compliance with the ATS recommendations.

*   FLEXIBILITY - Analysis of the results in a prefered way - 9 panel Wassermann diagram or individual setup of graphs.

*   USER-FRIENDLY - Automatic determination of anaerobic threshold by set method or manually.

 

TECHNICAL DATA

 

FLOW-MEASUREMENT

·   Principle              : Pneumotach       (variable                orifice)

·   Range                  : 0-20 l/s

·   Accuracy            : ±2%

·   Resolution          : 0,01 l/s

 

VOLUME-MEASUREMENT

·   Principle              : Digital Integration

·   Ventilation         : 300 l/min

·   Accuracy            : ± 2%

 

O2 MEASUREMENT

Principle :  Chemical Cell

Range : 10 to 45% O2

Resolution:  0.01% O2

Rise time : 80 ms

Accuracy : ± 0.1% O2

 

O2 MEASUREMENT

Principle :  Ultrasound

Range : 10 to 15% CO2

Resolution:  0.01% CO2

Rise time : <80 ms

Accuracy : ± 0.1% CO2

 

ELECTRICAL REQUIREMENTS

·   Power Consumption: Max. 30 VA

·   Voltage               : 24V

·   Frequency          : 50 to 60 Hz

 

POWERCUBE ERGO

Technical specifications

 

FEATURES

*    12 CHANEL ECG

- Use a full 12 chanel stress ECG or a pulse belt for sports application.

*    NON-INVASIVE MEASURING

- The only non-invasive method of measuring cardiac output.

*    PATIENT MANAGEMENT

- Easy patient management handling due to a shared database with other GANSHORN products or due to a full integration into SCHILLER SEMA.

 

 

ADMINISTRATIVE PROGRAMS

SQL Database                    

·    Report Generator                           

·    Multiuser license                            

·    User Predicted Values                   

·    GDT data transfer                         

·    HL7 Interface                

·    DICOM                            

·    Worklist                           

 

MEASUREMENT PROGRAMS & FEATURES        

·      Ergospirometry                               

·      Forced Spirometry/Flow-Volume               

·      Slow Spirometry                             

·      Offline Input of bloodgases (e.g. lactate)                  

·      MVV (Maximal Voluntary Ventilation)                    

·      Cardiac Output                              

·      Calorimetry                     

·      SpO2                

·      12-channel stress ECG                  

·      Polar pulse belt                               

·      Blood pressure measurement                      

·      Ergometer                        

·      Treadmil                          

·      Evaluation Software LFSport     

 

Quality Standards

·   Quality Management :  ISO 13485

·   FDA : 510(k) market clearance!*)

·   MDD 93/42/ECC :  CE Marked

·   Electrical safety :  EN 60601-1 (Third Edition)