    To get in, the lamp module is just turned back. The patient can sit comfortably on the lying surface first.

    Once the patient is lying on the lying surface, the lamp module is turned forward again.

    After the lamp shade has been closed, treatment is started on the computer and the exposure time counts down.

    After the desired dosage is reached, the UV lamps switch off automatically. The patient turns to the other side and the second part of the treatment can start without delay.

    At the end of the second part, the system will switch off auto¬matically, and the patient can leave the bed.

 

SIMPLE AND SAFE OPERATION

The medisun®-computer control permits precise dosage in J/cm2. The 6 single fields can be set to different strengths. The system can also be connected to the medisoft therapy management system with a network cable, and controlled and managed by remote PC, e.g. from the reception desk. The medical employees can use pre-set therapy plans and a comprehensive docu¬mentation in the patient database for this.

Safety and operating comfort leave nothing to be desired. The integrated patient history permits comprehensive insight into the current and all completed treatments. A comfor¬table protocol function permits printout of therapy protocols.

 

OPTIMISED THERAPY RANGE

The combination of UV xenon lamps and high-quality edge filters achieves a selective light spectrum between 340 nm and 460 nm, which ensures outstanding treatment success. The typical exposure times are between 10 and 30 minutes.

 

TECHNICAL DATA

    Mains : 400 V (3ph + N + PE), 7.0 kW (max.), CEE-16 A-wall outlet

    PC Interface :    Network (Ethernet), 8P8C-plug

    Energy Demand : Average 5 KWh

    Fuse     : 3x16 A, separate Fl-protection switch 0,03 A

    Dimensions W x L x H : 255 cm x 150 cm x 170 cm

    Required Standing Area  : W 350 cm xL 300 cm

    Weight Of Device              : 670 Kg

    Lying Surface    : Approx. 200 cm x 90 cm

    Lamp Modules  :6 modules with 12 lamps each

    Lamps : UV-Xenon lamps (energy-saving technology)

    Filter    : Special edge filters

    Protection Glass : Special acrylic glass as touch protection

    Spectral Range  : 340 to 460 nm, intensity: approx. 45-70 mW/cm2 (depending on distance)

    Patient Cooling  : 4 axial fans

    Room Venting   : Exhaust fan with 300m3/h adjustable (not enclosed) poss. additional air conditioning

-->

UV Therapy Bed/Cabin

UV Therapy Bed/Cabin

 

Model:   medisun® XENIA UVA-1

Make: Schulze & Böhm GmbH

Country of Orgin: Germany

 

CORTISONE-FREE THERAPY OF ATOPIC DERMATOSIS, CIRCUMSCRIBED SCLERODERMIA AND OTHER SKIN DISEASES

 

A TECHNOLOGY REVOLUTION

 

The medisun® XENIA UVA-1-bed uses a completely new and patented casing concept.

The lamp module can be easily turned back manually in spite of its size.

The patient is lying in a system that is open virtually at all times even during exposure, preventing feelings of claustrophobia.

The lamp module can be opened by the patient at any time. Electrical drives are not needed. This reduces maintenance costs.

The 72 special lamps produce barely any heat, but mostly UV and visible light. There¬fore, the expensive exhaust systems that are needed for conventional UVA-1-beds are not required here.

Another benefit is the option of partial expo¬sure with 6 individually dosable partial fields.

  After exposure, the lamps can be started again immedia-tely without any need to cool off first.

The patient is lying on a comfortable synthetic leather mattress that can be used hygienically with disposable covers.

EFFECTIVE THERAPY OF NEURODERMATITIS, CIRCUMSCRIBED SCLERODERMIA AND OTHER SKIN DISEASES

    To get in, the lamp module is just turned back. The patient can sit comfortably on the lying surface first.

    Once the patient is lying on the lying surface, the lamp module is turned forward again.

    After the lamp shade has been closed, treatment is started on the computer and the exposure time counts down.

    After the desired dosage is reached, the UV lamps switch off automatically. The patient turns to the other side and the second part of the treatment can start without delay.

    At the end of the second part, the system will switch off auto¬matically, and the patient can leave the bed.

 

SIMPLE AND SAFE OPERATION

The medisun®-computer control permits precise dosage in J/cm2. The 6 single fields can be set to different strengths. The system can also be connected to the medisoft therapy management system with a network cable, and controlled and managed by remote PC, e.g. from the reception desk. The medical employees can use pre-set therapy plans and a comprehensive docu¬mentation in the patient database for this.

Safety and operating comfort leave nothing to be desired. The integrated patient history permits comprehensive insight into the current and all completed treatments. A comfor¬table protocol function permits printout of therapy protocols.

 

OPTIMISED THERAPY RANGE

The combination of UV xenon lamps and high-quality edge filters achieves a selective light spectrum between 340 nm and 460 nm, which ensures outstanding treatment success. The typical exposure times are between 10 and 30 minutes.

 

TECHNICAL DATA

    Mains : 400 V (3ph + N + PE), 7.0 kW (max.), CEE-16 A-wall outlet

    PC Interface :    Network (Ethernet), 8P8C-plug

    Energy Demand : Average 5 KWh

    Fuse     : 3x16 A, separate Fl-protection switch 0,03 A

    Dimensions W x L x H : 255 cm x 150 cm x 170 cm

    Required Standing Area  : W 350 cm xL 300 cm

    Weight Of Device              : 670 Kg

    Lying Surface    : Approx. 200 cm x 90 cm

    Lamp Modules  :6 modules with 12 lamps each

    Lamps : UV-Xenon lamps (energy-saving technology)

    Filter    : Special edge filters

    Protection Glass : Special acrylic glass as touch protection

    Spectral Range  : 340 to 460 nm, intensity: approx. 45-70 mW/cm2 (depending on distance)

    Patient Cooling  : 4 axial fans

    Room Venting   : Exhaust fan with 300m3/h adjustable (not enclosed) poss. additional air conditioning